How to fix ghost implant abutment?

Discussion in 'exocad' started by Andre A Alves Souza, Jan 21, 2020.

  1. Someone now how to fix it? The brazilian factory (conexão implants) doesnt have the stl file of this abutment! Ive tryed to scan it once again!! It is so bad to do the prosthetic of another professional, because ive dont use this brand!!
     

    Attached Files:

    Last edited: Jan 21, 2020
  2. cadfan

    cadfan Moderator Staff Member

    you have the ti base or just an impression
     
  3. Hi i just have the abutment impression!!! But i can aks for the lab for send me the implant base!
     
  4. Ive tryed to download this factory implant library but they only have UCLA files....what i can do for close those wholes?
     
  5. cadfan

    cadfan Moderator Staff Member

    just make a second die only and scan load as multi die register done
     
    2thm8kr and Andre A Alves Souza like this.
  6. I can do the second die on model creator? Or the lab need to scan just the die? I dont know how to do it! But the multi die register i know it!!
     
  7. cadfan

    cadfan Moderator Staff Member

    just rescan without holes your problem at the moment are the big holes if they have the org ti base they could although scan this the sky and your imagination is the only limit ;):)
     
    2thm8kr likes this.
  8. Thanks mate! You are awesome!!
     

Share This Page