Scanners and Markers

Discussion in '3D Scanners' started by cadfan, May 9, 2019.

  1. cadfan

    cadfan Moderator Staff Member

    Have you ever tried to check your scanmarkers and scanner ???
     

    Attached Files:

    jmn, tenretni and 2thm8kr like this.
  2. 2thm8kr

    2thm8kr ɹotɐɹʇsıuıɯqA Staff Member

    I have measured a few different implant company scan bodies and found them all to have at least a little deviation. (with cheap Chinese micrometer)
    When I get some time I'm going to scan and see how they compare to micrometer.

    Mr. Cadfan, all your scan bodies measure the same or really close?
     
  3. cadfan

    cadfan Moderator Staff Member

    @Mr. 2thm8kr not all of them are so easy to measure but most are from two sources and they are in that range buy callibrated mytoyo mikrometer screw you find nothing better 2 micron repeatability.
     
    jmn and 2thm8kr like this.
  4. tenretni

    tenretni New Member

    Doesn't thermal expansion come in play when we talking 3/1000 mm?
    I don't think it is a problem? Or I'm I wrong?

    I think you should be more worried about the linear expansion in gypsum, that is if you have more then one implant. There you have an expansion of more than 0.05%.

    Cheers!
     
  5. cadfan

    cadfan Moderator Staff Member

    I am not worried about anything because i know my numbers and each counts !!! on 3 micron we talk first about repeatability of the microscrew which is two :coffee
     
    jmn likes this.